The challenges of the even surface and performance have been overcome.
Uw ≥ 1.43 W/m²K
Thermal Insulation
45 dB
Sound Reduction
750 Pa
Air Permeability
1,200 Pa
Watertightness
DESIGN
This flexible solution seamlessly supports advanced architectural design and engineering requirements. It secures the space against the elements of nature while allowing light to function to the benefit of interior design.
LARGE GRIDS
The ability to create large grids with multiple mullion-transom connection solutions provides significant flexibility in architectural design and construction. By utilizing various connection solutions, designers can enhance the stability and aesthetic appeal of the grid system.
ROUNDED STRUCTURE SOLUTIONS
The option of full-circle constructions without the use of angular pressure plates offers many architectural and construction advantages. The use of special gaskets allows angles of up to 0.349 rad per column.
ULTIMATE COMPATIBILITY
FS50 facade system offers flexibility and combination with the company's thermal insulation systems, using a single additional thermal insulation profile. This makes the FS50 an ideal choice for modern architectural applications.
TECHNOLOGY
Facades are always fascinating because they represent a constructional and aesthetic challenge. Their large-scale surface must excel in design and simultaneously achieve performance.
ELVIAL technology ensures you enjoy all the non negotiables that ascribe value to the aesthetic excellence; advanced thermal insulation that can be adjusted to fit the Passive House A+ specifications, reliable watertightness and incomparable durability.
Identity
| Mullion and Transom Depth | 50 mm | |
| Mullion Height | 14 up to 200 mm | |
| Transom Height | First level | 6 up to 205 mm |
| Second level | 49 up to 199 mm | |
| Max Glass Thickness | 62 mm |
Performance
| ENERGY | |||
| Thermal Insulation | EN ISO 10077-2 | Uf ≥ 0.6 W/m²K | |
| Ucw ≥ 0.8 W/m²K | |||
| Construction 4,000 x 3,000 mm | Double glazing, Ug = 1.1 W/m²K with Swisspacer Ultimate | Uw ≥ 1.43 W/m²K | |
| COMFORT | |||
| Air Permeability | EN 12152 | Class AE | [750 Pa] |
| Watertightness | EN 12154 | Class RE 1200 | [1,200 Pa] |
| Resistance to Wind Load | EN 13116 | ± 2.0 kN/m² | Design load |
| ± 3.0 kN/m² | Safety load | ||
| Sound Reduction | EN 10140-2 | 45 dB | Glazing 66.2/20/44.2 |
| Bullet Resistance | EN 1522 | FB 3 S | |
| NORTH AMERICA TESTED | |||
| Air Permeability | ASTM E283-04 | < 0.2 L/s*m² | [300 Pa] |
| Watertightness | ASTM E331-00 / AAMA 501.1-17 | 720 Pa | |
| Resistance to Wind Load | ASTM E330-14 | ± 2,000 Pa | Design load |
| ± 3,000 Pa | Safety load |